HemosIL Products for ACL Analyzers

HemosIL Liquid Antithrombin XL

Chromogenic / IVD

Catalog #: 20003800

Intended use

Automated chromogenic assay for the quantitative determination of Antithrombin in human citrated plasma on the ACL Futura/ACL Advance and ACL TOP Systems.

Summary and principle

Antithrombin (AT) or Heparin Cofactor I is the major inhibitor of blood coagulation and is essential for effective heparin therapy. By inhibiting the coagulation proteases, especially thrombin, FXa and FIXa, AT prevents uncontrolled coagulation and thrombosis.

Antithrombin deficiency is associated with a high risk of thromboembolic disorders.

Liquid Antithrombin XL can be used to exclude or diagnose hereditary deficiencyin patients with a tendency toward thromboembolism, in pre-operative stages, before prescription of oral contraceptives, DIC6, nephrotic syndromes, liver diseasesand in therapy with heparin or antithrombin concentrates.

The Liquid Antithrombin XL kit is an assay based on a synthetic chromogenic substrate and on FXa inactivation. As a consequence, the method is specific and not influenced by Heparin Cofactor II. Antithrombin levels in patient plasma are measured automatically on IL Coagulation Systems in two stages:

  1. Incubation of the plasma with the Factor Xa reagent in the presence of an excess of heparin.
  2. Quantification of the residual FXa activity with a synthetic chromogenic substrate. The paranitroaniline released is monitored kinetically at 405 nm and is inversely proportional to the Antithrombin level in the test sample.

Composition

Chromogenic substrate (Cat. No. 0020003820): 4 x 2.5 mL vials of the chromogenic substrate S-2765, N-α-Z-D-Arg-Gly-Arg-pNA.2HCl (7.5 mg/vial), surfactant and buffer. Opened reagent is stable: 5 weeks at 2-8°C in the original vial or 3 days at 15°C on the ACL Futura®, ACL Advance and ACL TOPTM Systems. Do not freeze.

Factor Xa reagent (Cat. No. 0020003810): 4 x 6 mL vials of a solution containing bovine Factor Xa (60 nkat/vial), heparin, buffer, bovine serum albumin and preservatives. Opened reagent is stable: 5 weeks at 2-8°C in the original vial or 3 days at 15°C on ACL Futura, ACL Advance and ACL TOP Systems. Do not freeze.

Unopened reagents are stable until the expiration date shown on the vial when stored at 2-8°C. For optimal stability remove reagents from the system and store them at 2-8°C in the original vial.

Additional reagents and control plasmas
The following are not supplied with the kit and must be purchased separately.

  • Calibration plasma (Cat. No. 0020000000)
  • Normal Control (Cat. No. 0020003120)
  • Special Test Control Level 1 (Cat. No. 0020010100)
  • Special Test Control Level 2 (Cat. No. 0020010200)
  • Low Abnormal Control (Cat. No. 0020003220)
  • High Abnormal Control (Cat. No. 0020003320)
  • Factor diluent (Cat. No. 0009757600)
  • Cleaning solution (Cat. No. 0009831700)
  • Cleaning agent (Cat. No. 0009832700)

Downloads

Name Type Size
HemosIL Liquid Antithrombin XL Package Insert application/pdf 106.28 kB
Instrumentation Laboratory Hemostasis Catalog application/pdf 908.14 kB